Products About us Service News Career Download Contact Online Catalogue
 
send

IXOSIL Joints



IXOSIL High-Voltage Slip-on Joints.  

IXOSIL High-Voltage Slip-on Joints.



IXOSIL slip-on joints essentially consist of premoulded slip-on silicone parts. This enables the secure and efficient connection of two polymeric-insulated cables (XLPE, EPR). The proven slip-on technique ensures minimum installation time and a maximum operation reliability. The tested and applied material complies with all electrical, mechanical and thermal requirements for rebuilding the insulation of a cable. IXOSIL slip-on joint is available in one-piece and threepart set up and it may be used for connection of copper as well as aluminium cables. Both joints are available in different variants.
     
IXOSIL One-Piece Slip-on Joints

IXOSIL One-Piece Slip-on Joints

The one-piece slip-on joints are available for voltages from 72,5 kV to 300 kV. Due to the one-piece construction the joints are extremely compact in size. The space required in a joint bay therefore is reduced to a minimum. Each size of the silicone body covers a range of different insulation diameters.

Screen treatment (Type designation)
DO: no screen version
DE: screen version earthing tap on one side
XL: screen version with 2 single-wire bonding leads
XK: screen version with 1 concentric bonding cable
   
Water diffusion barrier (Type designation)
F: aluminium foil water diffusion barrier
M: copper metal housing water diffusion barrier
   
Protective housing (Type designation)
S: heat-shrinkable sleeve housing
G: PE protective housing
R: heat-shrinkable sleeve housing with repair collar

     
IXOSIL Threepart Slip-on Joint  

IXOSIL Threepart Slip-on Joint

The threepart slip-on joint is available for voltages from 72,5 kV to 170 kV. The well-tried threepart construction of this joint enables cables of different types and dimensions to be connected. For example a 630 mm² EPR cable can be connected to a 500 mm² XLPE cable.

 
 
Joint Types
MSA DO
MSA S
MSA MS
   
MSA DO
MSA S
MSA MS
   
Screen transition
heat-shrink
Metal water barrier with shrink sleeve
 
Joint Types  
MSA XL or XK
MSA G
MSA MG
   
MSA XL or XK
MSA G
MSA MG
   
Screen interruption with screen take out
Plastic casing with filling compound
Metal water barrier with plastic casing
 
Max. working voltage
Um (kV)
Standards Rated voltage Nominal withstand
lightning impulse voltage (BIL)
72,5   IEC60840   60 – 69   325  
123   IEC60840   110 – 115   550  
145   IEC60840   132 – 138   650  
170   IEC60840   150 – 161   750  
245   IEC62067   220 – 230   1050  
300   IEC62067   275 – 287   1050  
   

 

 

Partial discharge measurement (pC) Conductor cross section Diameter over cable insulation (prepared) (mm) Net weight approx. (kg)
< 5 150 – 1200   37 – 87   72 – 90
< 5 240 – 2000   45 – 103   50 – 130
< 5 240 – 2000   45 – 103   80 – 160
< 5 240 – 2000   45 – 103   80 – 160
< 5 240 – 2000   69 – 102   80 – 200
< 5 240 – 2000   69 – 102   80 – 220
 
CABLE SYSTEMS | COMPONENTS | OVERHEAD LINES | RAILWAY CATENARY SYSTEMS